NOTE: Tank must be 
mounted in vertical position
for proper Ventilation
LP/Propane Tank Connection
conducting Propane
and Natural Gas CAN1-
8.3 standard. (See
LP/Propane tank
requirements below). Each
tank is supplied with a dust
cap. Place dust cap on
cylinder valve outlet whenever the
cylinder is not in use. Only install the
type of dust cap on the cylinder valve
outlet that is provided with the cylinder
valve. Other types of caps or plugs may
result in leakage of propane. 
Connect the regulator to the grill unit by
screwing the 3/8” flare coupling to the
3/8” flare adapter. Connect to the tank
valve by screwing the Type 1, QCC-
Connection
Operating Pressure
1/2” (1.3 cm) NPT male with a 3/8” 
(.95) flare adapter
10.0” W.C.P. LP/Propane.
Outdoor grills orificed for use with
LP/Propane gas come equipped with a high
capacity hose/regulator assembly for
connection to a standard 20 lb. LP/Propane
cylinder equipped with a Type 1, QCC-1
connector. Hose assembly must comply with
Elastomeric Composite Hose and Couplings
for conducting Propane and Natural Gas,
CAN/CGA-8.1 standard or the Theromplastic
Hose and Hose Couplings for 
connector to the LP/Propane tank. Open the
tank valve and check the connection between
the  regulator  and  the  Type  1,  QCC-1  fitting
for  leaks  with  a  soapy  water  solution.  If
bubbles  appear,  tighten  the  connection.
Repeat  until  all  leaks  have  been  stopped.
ALWAYS  CHECK  FOR  LEAKS  AFTER  EVERY
LP/PROPANE  TANK  CHANGE.  Any  joint
sealant used must be an approved type and
be resistive to the actions of LP/Propane gas.
25
A  dented  or  rusty  LP/Propane  tank  may  be
hazardous  and  should  be  checked  by  your
tank  supplier.  Never  use  a  cylinder  with  a
damaged valve. All tanks should be equipped
with 
an 
OPD 
(overfilling 
protection
device).  This  is  a  DOT  requirement  for  all
tanks  purchased  after  October  1,  1998  and
will ensure that the tank is not overfilled. The
LP/Propane tank should be a standard 5-gal,
20 lb. gas cylinder tank approximately 12” in
diameter  and  18”  high  which  must  be
constructed  and  marked  in  accordance  with
the  Specifications  for  LP/Propane  Gas
Cylinders  of  the  U.S.  Department  of
Transportation  (D.O.T.)  or  the  National
Standard  of  Canada,  CAN/CSA-B339,
Cylinders, 
Spheres 
and 
Tubes 
for
Transportation  of  Dangerous  Goods;  and
Commission. The cylinder connection device
must be compatible with the Type 1, QCC-1
connector on the outdoor cooking appliance. 
All  LP/Propane  tanks  must  be  mounted  in  a
vertical  position  for  proper  ventilation.  The
cylinder  must  be  provided  with  a  shut-off
valve  terminating  in  an  LP/Propane  gas
supply  cylinder  valve  outlet  specified.  The
cylinder supply system must be arranged for
vapor  withdrawal  and  provided  with  a  listed
overfilling prevention device. If the appliance
is  stored  indoors  the  cylinder  must  be
disconnected  and  removed  from  the
appliance.  Each  tank  is  supplied  with  a  dust
cap.  Place  dust  cap  on  cylinder  valve  outlet
whenever  the  cylinder  is  not  in  use.  Only
install  the  type  of  dust  cap  on  the  cylinder
valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result
in  leakage  of  propane.  The  cylinder  used
must  include  a  collar  to  protect  the  cylinder
valve. Cylinders must be stored outdoors in a
well-vented area out of the reach of children.
BUILT-IN INSTALLATIONS
Built-in installations must be plumbed using a
fixed/hard  line  if  the  unit  is  going  to  be
operated at a distance exceeding 3 feet (0.91
meters) from the fuel supply per ANSI Z21.24
CSA.  Also, in a built-in construction where an
LP/Propane  tank  is  going  to  be  used,  there
MUST be some type of support (braces, cut-
out, etc.) to prevent tank from moving within
the installation.  The support must also allow
the LP/Propane tank to withstand a horizontal
tipping force equal to the weight of the tank
without  tipping  over.    The  tank  can  not  tip
over or deflect more than 1.00 inch when a 38
lb.  horizontal  force  is  applied  to  a  20  lb.
LP/Propane tank.
LP/Propane Tank Requirements