Dimensions
19”W X 6.50”D X 1.75”H
Weight
5.5 Lbs
Input Connections
balanced XLR & 1/4” TRS
Output Connections
balanced XLR & 1/4” TRS 
Input Impedance XLR, 1/4” 
20K ohms, 1M ohms
Output Impedance XLR, 1/4” 600 ohm, 300 ohms
Maximum Input Level, XLR
+15dBm
Maximum Input Level, 1/4”
+15dBm
Maximum Output Level, XLR +26dBm
Maximum Output Level, 1/4” +20dBm
Frequency Response
10Hz to 20KHz (+/- .5dB)
Dynamic Range
>105dB (20-20kHz)
THD @ 0dB out:
<0.1% (typical)
Equivalent Input Noise (EIN)
XLR to XLR
-100dBm (‘A’ weighted)
1/4” to 1/4”
-100dBm (‘A’ weighted)
Attack Time
6.5ms
Release Time
Fast-200ms, Auto-70ms-1sec.
Slope
Comp - 2.3:1, Limit >6:1
Max. Attenuation
28dB
Power Requirements
95-125VAC 10 W (USA) 
Internal fuse. Other power 
requirements configured for 
country of destination.
A R T retains a policy of constant product improvement;
therefore, specifications are subject to change without
notice. A R T reserves the right to make changes in design
or make additions to or improvements upon this product
without any obligation to install the same on products pre-
viously manufactured.
W
We
e’’rre
e  O
On
nlliin
ne
e!!
For Product information, questions, applications, tips,
answers and general discussion with A R T employees look
for A R T on the Internet. Check out our Web Page at:
http://www.artroch.com. 
email: artroch@aol.com
apply gain to bring the processed signal back up to unity
(same as input level). To properly set the output level,
adjust the control while switching between Active and
Bypass. When these two levels are equal in volume, the out-
put control is set properly. 
G
Ga
aiin
n  R
Re
ed
du
uc
cttiio
on
n  M
Me
ette
err
The four-LED meter is provided to give a visual indication
of how much compression is taking place. The Threshold
LED will light when the input signal reaches the set thresh-
old level. The remaining three LEDs indicate how much the
signal is being compressed. Their values are -3dB, -6dB and
-12dB.
A
Ap
pp
plliic
ca
attiio
on
nss
C
Co
om
mp
prre
esssso
orr//  lliim
miitte
err
The main application of the Dual Levelar is to control the
dynamic range of a signal level. Plug a line level (post pre-
amplifier or other gain stage) source into either input and
set the threshold and output controls to provide the
desired amount of compression to the input signal.
S
Stte
erre
eo
o  m
miix
x  a
an
nd
d  m
ma
asstte
erriin
ng
g
Because of its low noise and excellent tonal qualities, the
Dual Levelar is ideal for running mixes through before
recording to DAT or cassette. Used as a mastering device,
the Dual Levelar is capable of adding warmth and impact to
the overall signal level.
V
Vo
oc
ca
all  a
an
nd
d  iin
nssttrru
um
me
en
ntt  lle
ev
ve
elllliin
ng
g
The musical nature of the Dual Levelar makes it ideal for
use on a wide range of instruments and vocals. Place the
Dual Levelar into a channel insert, after a preamplifier, or
from a direct output of a channel of a mixer. Adjust the
controls of the Dual Levelar to achieve the desired amount
of compression.
6
6
7
7