EP-15 Fluid Level Calibration 
The default calibration for the EP-15 Fluid Level is just as accurate as standard 
fluid level gauges. If, however, the tank has an irregular shape or greater 
accuracy is needed, calibration is recommended. There are three calibration 
options: 2-Point, 3-Point and 5-Point. 
2-Point Calibration 
A 2-point calibration is best suited for rectangular or square-shaped tanks, 
where the capacity of the top half of the tank matches the capacity in the 
lower half of the tank. In a two-point calibration, you will set two points, 
one each for empty and full levels. You can begin calibration at either of 
the two points, but we recommend starting with an empty tank. You will 
fill the tank to complete calibration.  
1. Press 
MENU| MENU
, use 
↓ ↑  to select 
NMEA
 
2000
 and press 
ENT
2. Highlight 
B
US 
S
ETUP
 and press 
ENT
, which will open the Bus Configuration 
menu. A list of network devices will be at the top of the page.   
3. Select the EP-15 Fluid Level and press 
ENT
4. Press 
↓ to select 
C
ALIBRATE
 and press 
ENT
. The Device Calibration menu 
will appear. Instructions on Calibration will be listed at the top of the menu.  
5. Highlight
 N
UM 
P
TS
,
 
press
 ENT 
and select
 2. 
Press 
ENT
.
 
6.
 Select F
LUID 
L
EVEL
, press ENT, then select E
MPTY 
L
EVEL
 and 
press 
ENT.  
7. Make sure the fuel tank is empty, highlight 
C
ALIBRATE
 and press 
ENT
The following message will appear: Empty Level Calibration Completed. 
Press ENT.
 
8. 
Fill up your tank, highlight
 F
LUID 
L
EVEL
 
and press
 ENT
9. 
Select
 F
ULL 
L
EVEL
 
and press
 ENT
Highlight 
C
ALIBRATE
 
and press
 ENT.  
10. 
The following message will appear
Full level Calibration Completed.
 
Press 
ENT
, then press 
EXIT
 repeatedly to get back to the main display. 
   
 
Calibrate is highlighted on the device configuration menu (left).  
Calibration menu (right) with calibration instructions listed at the top.