3-Point Calibration 
3-point calibration is designed for tanks that vary in shape from the top 
to the bottom. You can begin calibration at any point in the 3-point 
process, but we recommend starting calibration with an empty tank.  
In a 3-point calibration, you will set three points, one each for empty, 
half and full levels. 
1. Press 
MENU| MENU
, use 
↓ ↑  to select 
NMEA
 
2000
 and press 
ENT
2. Highlight 
B
US 
S
ETUP
 and press 
ENT
, which will open the Bus 
Configuration menu. A list of network devices will be at the top of the 
page. 3. Select the EP-15 Fluid Level and press 
ENT
4. Press 
↓ to select 
C
ALIBRATE
 and press 
ENT
. The Device Calibration 
menu will appear. 
5. Highlight 
N
UM 
P
TS
, press 
ENT
 and select 
3
. Press 
ENT
6. 
Make sure your tank is empty, then highlight
  F
LUID 
L
EVEL
 
and press
 
ENT
.
 Select E
MPTY LEVEL 
and press ENT.  
7. 
Select
  C
ALIBRATE
 and press ENT
. The following message will appear: 
Empty Level Calibration Completed. Press 
ENTER
.
 
8. 
Add half a tank of fuel, highlight
  F
LUID 
L
EVEL
 
and press
  ENT
.
 
Select
 
H
ALF LEVEL 
and press
 ENT.  
9. 
Select
  C
ALIBRATE
 
and press
 ENT
. The following message will appear: 
Half Level Calibration Completed. Press 
ENT
10. Fill up the tank, then
 
highlight
  F
LUID 
L
EVEL
 
and press
  ENT
.
 
Select
 
F
ULL LEVEL 
and press
 ENT
11. 
Highlight
  C
ALIBRATE
 
and press
 ENT
. The following message will 
appear:  Full Level Calibration Completed. Press 
ENT
, then press 
EXIT
 
repeatedly to get back to the main display. 
 
 
 
Num Pts menu with 5-point calibration selected (left). Half level 
selected on Fluid Level menu (center). Calibration Done window 
(right).