3com S7906E インストール手順
1-8
Enabling the Sending of Flush Messages
Follow these steps to enable the sending of flush messages:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Create a smart link group and enter
smart link group view
smart link group view
smart-link group group-id
Required
Enable flush update in the specified
control VLAN
control VLAN
flush enable [ control-vlan
vlan-id ]
vlan-id ]
Optional
By default, flush
update is enabled,
and VLAN 1 is the
control VLAN.
update is enabled,
and VLAN 1 is the
control VLAN.
z
The control VLAN configured for a smart link group must be different from that configured for any
other smart link group.
z
Make sure that the configured control VLAN already exists, and assign the smart link group
member ports to the control VLAN.
z
Do not remove the control VLAN. Otherwise, flush messages cannot be sent properly.
Configuring the Collaboration Between Smart Link and CC of CFD
Follow these steps to configure the collaboration between Smart Link and the CC function of CFD on a
smart link member port:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter Ethernet interface view
interface interface-type
interface-number
interface-number
—
Configure the collaboration between
Smart Link and the CC function of CFD
on the port
Smart Link and the CC function of CFD
on the port
port smart-link group group-id
track cfd cc
track cfd cc
Optional
By default, the
collaboration between
Smart Link and the
CC function of CFD is
not configured.
collaboration between
Smart Link and the
CC function of CFD is
not configured.
When configuring the collaboration between Smart Link and the CC function of CFD on a smart link
member port, make sure that the control VLAN of the smart link group to which the port belongs
matches the detection VLAN of the CC function of CFD.