Инструкции По Установке для 3com S7906E

Скачать
Страница из 2621
 
1-8 
 
Enabling the Sending of Flush Messages 
Follow these steps to enable the sending of flush messages: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Create a smart link group and enter 
smart link group view 
smart-link group group-id 
Required 
Enable flush update in the specified 
control VLAN 
flush enable [ control-vlan 
vlan-id 
Optional 
By default, flush 
update is enabled, 
and VLAN 1 is the 
control VLAN.  
 
 
The control VLAN configured for a smart link group must be different from that configured for any 
other smart link group.  
Make sure that the configured control VLAN already exists, and assign the smart link group 
member ports to the control VLAN.  
Do not remove the control VLAN. Otherwise, flush messages cannot be sent properly.  
 
Configuring the Collaboration Between Smart Link and CC of CFD 
Follow these steps to configure the collaboration between Smart Link and the CC function of CFD on a 
smart link member port: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter Ethernet interface view 
interface interface-type 
interface-number
 
— 
Configure the collaboration between 
Smart Link and the CC function of CFD 
on the port 
port smart-link group group-id 
track cfd cc
 
Optional 
By default, the 
collaboration between 
Smart Link and the 
CC function of CFD is 
not configured.  
 
 
When configuring the collaboration between Smart Link and the CC function of CFD on a smart link 
member port, make sure that the control VLAN of the smart link group to which the port belongs 
matches the detection VLAN of the CC function of CFD.