Canon imageFORMULA DR-G1130 マニュアル

ページ / 126
3-23
Chapter 3   Basic Operation
4.
Close the upper unit gently. Then press it at both 
ends to make sure it is fully closed.
5.
Check to verify the last saved image, and perform 
rescanning.
IMPORTANT
• Even if a document is ejected onto the eject tray, the scanned 
image of the document may not be saved. Before rescanning, 
always check the last saved image.
• Before rescanning, straighten documents that were detected 
as skewed.
• Before rescanning, remove any staples that were detected in 
documents.
Place the document removed from inside the scanner in 
front of the other documents in the feed tray, and press the 
Start key to resume scanning.
Handling a Double Feed
When a double feed is detected while scanning, the document 
pages for which double feeding was detected are ejected at the 
eject outlet, an error message appears on the Control Panel 
display, and feeding stops.
IMPORTANT
When a double feed is detected, the following process occurs, and 
messages appear according to the Rapid Recovery System setting 
in the ISIS/TWAIN driver.
■ When the Rapid Recovery System is Disabled
• When the Rapid Recovery System is disabled, images scanned 
before the double feed are saved as files, scanning finishes, and 
the following error message is displayed. 
When detecting double feeds by document length
Start Key