The following figure shows the product label for the UTM9S: 
Figure 17. 
Choose a Location for the UTM
The UTM is suitable for use in an office environment where it can be freestanding (on its 
runner feet) or mounted into a standard 19-inch equipment rack. Alternatively, you can 
rack-mount the UTM in a wiring closet or equipment room. A rack-mounting kit, containing 
two mounting brackets and four screws, is provided in the package for the multiple WAN port 
models.
Consider the following when deciding where to position the UTM:
•     
The unit is accessible, and cables can be connected easily.
•     
Cabling is away from sources of electrical noise. These include lift shafts, microwave 
ovens, and air-conditioning units. 
•     
Water or moisture cannot enter the case of the unit. 
•     
Airflow around the unit and through the vents in the side of the case is not restricted. 
Provide a minimum of 25 mm or 1 inch clearance.
•     
The air is as free of dust as possible.
•     
Temperature operating limits are not likely to be exceeded. Install the unit in a clean, 
air-conditioned environment. For information about the recommended operating 
temperatures for the UTM, see 