Netgear XCM8810 - 8800 SERIES 10-SLOT CHASSIS SWITCH ユーザーズマニュアル

ページ / 968
  Chapter 8.  Status Monitoring and Statistics    
|
    
213
NETGEAR 8800 User Manual 
•     
Revision—The revision number of the fan.
•     
Odometer—Specifies the power-on date and how long the fan tray has been operating 
since it was first powered-on.
Viewing the System Temperature
Depending on your switch model, you can view the temperature in Celsius of the I/O 
modules, management modules, power controllers, power supplies, and fan trays installed in 
your switch. In addition, depending on the software version running on your switch, additional 
or different temperature information might be displayed.
This section describes the following topics: 
To view the system temperature, use the following command:
show temperature
System Temperature Output
Modular Switches Only
On a modular switch, the output includes the current temperature and operating status of the 
I/O modules, management modules, and power controllers. 
The following output shows a sample display of the current temperature and operating status 
of the installed modules and power controllers:
XCM8810.4 # show temperature
Field Replaceable Units               Temp (C)   Status   Min  Normal  Max
--------------------------------------------------------------------------
Slot-1         :
Slot-2         :
Slot-3         :
Slot-4         : XCM8824F                23.00   Normal   -10    0-50   60
Slot-5         : XCM888F                 25.00   Normal   -10    0-50   60
Slot-6         :
Slot-7         : XCM8848T(P)             28.50   Normal   -10    0-50   60
Slot-8         : XCM8808X                31.00   Normal   -10    0-50   60
Slot-9         :
Slot-10        :
MSM-A          : XCM88S1                 29.00   Normal   -10    0-50   60
MSM-B          :
PSUCTRL-1      :                         35.71   Normal   -10    0-50   60