Netgear M6100 – Campus Edge and SMB Core Chassis Switches ユーザーガイド

ページ / 564
Configuring System Information 
22
M6100 Web Management User Guide 
Click Update to update the page with the latest information on the switch.
System CPU Status
Use this page to display the system resources.
To display the System Resource page, click System > Management > System CPU Status
A screen similar to the following is displayed.
Internal AC-1, Internal AC-2, etc.
Indicates the status of the appropriate power module 
in each unit. Status can be any of the following:
• 
Operational
 
  Power module is present and 
functioning properly.
• 
Powering
 
  Main power is failed or disconnected 
but RPS provides power to the switch.
• 
Not Present —
  Power module is not present in 
the slot.
• 
Not powered
  —
  Power module is present but not 
connected to the power source.
• 
Not powering —
  Power module is present and 
connected but the switch uses another power 
source.
• 
Incompatible —
  Power module is present but 
incompatible.
• 
Failed —
  Power module is present, but power 
cable is not plugged-in or a bad cable is 
plugged-in.
PoE Version
Version of the PoE controller FW image.
N/A indicates that the Poe is not supported by the 
unit.
MAX PoE
Indicates the status of maximum PoE power 
available on the switch as follows:
• 
ON
 
  Indicates less than 10W of PoE power 
available for another device.
• 
OFF
 
  Indicates at least 10W of PoE power 
available for another device.
• 
N/A
 
  Indicates that PoE is not supported by the 
unit.
PoE D-Card Type
Indicates the type of the PoE daughter card plugged 
in. Possible values are:
• 
XCM89P
 
  PoE card supporting 802.3at 
standard (backward compatible with 802.3af).
• 
XCM89UP
 
  PoE card supporting UPOE 
pre-standard (backward compatible with 
802.3af/802.3at).
• 
Not Installed
 
  PoE card is not plugged in.
Field
Description