Netgear XCM8806 - 8800 SERIES 6-SLOT CHASSIS SWITCH ユーザーズマニュアル
Appendix C. Troubleshooting
|
853
NETGEAR 8800 User Manual
•
First Recorded Start Date—The date that the component was powered-up and began
running
Depending on the software version running on your switch, the modules installed in your
switch, and the type of switch you have, additional or different odometer information may be
displayed.
switch, and the type of switch you have, additional or different odometer information may be
displayed.
The following is sample output from a NETGEAR 8800 series switch:
XCM8810.5 # show odometers
Service First Recorded
Field Replaceable Units Days Start Date
---------------------------------------------------------------
Chassis : XCM8810 48 Dec-14-2010
Slot-1 : XCM8848T 47 Dec-16-2010
Slot-2 :
Slot-3 :
Slot-4 :
Slot-5 :
Slot-6 :
Slot-7 :
Slot-8 : XCM8848T 27 Jan-13-2011
Slot-9 :
Slot-10 : XCM8824F 47 Dec-13-2010
MSM-A : XCM88S1 47 Jan-06-2011
MSM-B :
PSUCTRL-1 : 48 Dec-14-2010
PSUCTRL-2 : 48 Dec-14-2010
Temperature Operating Range
XCM8800 has its own temperature operating range of -10° to 50° C.
On a modular switch, any module in the switch that is reported outside this range is
automatically shut down. XCM8800 specifically performs a reboot on any MSM that falls
outside the expected range. This behavior is expected and not indicative of a problem. If you
experience this behavior more than once, contact NETGEAR Technical Support.
automatically shut down. XCM8800 specifically performs a reboot on any MSM that falls
outside the expected range. This behavior is expected and not indicative of a problem. If you
experience this behavior more than once, contact NETGEAR Technical Support.
Corrupted BootROM on NETGEAR 8800 Series Switches
If your default BootROM image becomes corrupted, you can force the MSM to boot from an
alternate BootROM image, by inserting a pen into the Alternate (A) and Reset (R) holes on
the NETGEAR 8800 series MSM and applying pressure. The alternate BootROM image also
prints boot progress indicators, and you can later use this alternate image to re-install a new
default BootROM image. Finally, a corrupted compact flash can be recovered from either the
Alternate or Default BootROM.
alternate BootROM image, by inserting a pen into the Alternate (A) and Reset (R) holes on
the NETGEAR 8800 series MSM and applying pressure. The alternate BootROM image also
prints boot progress indicators, and you can later use this alternate image to re-install a new
default BootROM image. Finally, a corrupted compact flash can be recovered from either the
Alternate or Default BootROM.