Netgear GS510TP – ProSAFE 8-Port Gigabit Smart Switch with PoE and 2 fiber SFP ports 管理者ガイド
![Netgear](https://files.manualsbrain.com/attachments/cf1ad5de25a3f8d6c88ef0ab489c1b137eebe11f/common/fit/150/50/17742d1e0cdacf24edeb88c30757620088415c5f7699f69b4517262e21e0/brand_logo.jpeg)
Getting Started
27
GS510TP and GS110T Gigabit Smart Switches
To access configuration information for SNMPv1 or SNMPv2, click System > SNMP >
SNMPv1/v2 and click the page that contains the information to configure.
SNMPv1/v2 and click the page that contains the information to configure.
Interface Naming Convention
The GS510TP and GS110T switch software supports physical and logical interfaces.
Interfaces are identified by their type and the interface number. The physical ports are gigabit
interfaces and are numbered on the front panel. You configure the logical interfaces by using
the software. The following table describes the naming convention for all interfaces available
on the switch.
Interfaces are identified by their type and the interface number. The physical ports are gigabit
interfaces and are numbered on the front panel. You configure the logical interfaces by using
the software. The following table describes the naming convention for all interfaces available
on the switch.
Table 2. Interface Naming Conventions
Interface
Description
Example
Physical
The physical ports are gigabit Ethernet
interfaces and are numbered sequentially
starting from one.
interfaces and are numbered sequentially
starting from one.
g1, g2, g3
Link Aggregation Group (LAG)
LAG interfaces are logical interfaces that are
only used for bridging functions.
only used for bridging functions.
l1, l2, l3
LAG1, LAG2
LAG1, LAG2
CPU Management Interface
This is the internal switch interface responsible
for the switch base MAC address. This interface
is not configurable and is always listed in the
MAC Address Table.
for the switch base MAC address. This interface
is not configurable and is always listed in the
MAC Address Table.
c1