KitchenAid 36" Convertible Island-Mount 400-CFM Glass Canopy Hood インストールガイド

ページ / 32
5
Product Dimensions
 * Vented installations only
 ** Non-vented (recirculating) installations only
Installation Dimensions
IMPORTANT:
Minimum distance “C”: 24" (61 cm) from electric cooking 
surface, 27" (68.6 cm) from gas cooking surface
Suggested maximum distance “C”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights. 
See the following chart.
Vented Installations
Min. ceiling height
Max. ceiling height
Electric cooking 
surface
7' 8" (2.34 m)
9' 10" (3 m)
Gas cooking 
surface
7' 11" (2.41 m)
9' 10" (3 m)
Non-Vented (Recirculating) Installations
Min. ceiling height
Max. ceiling height
Electric cooking 
surface
7' 8" (2.34 m)
10' 3" (3.12 m)
Gas cooking 
surface
7' 11" (2.41 m)
10' 3" (3.12 m)
NOTE: The range hood chimneys are adjustable and designed 
to meet varying ceiling or soffit heights depending on the 
distance “C” between the bottom of the range hood and the 
cooking surface. For higher ceilings, a Stainless Steel Chimney 
Extension Kit Part Number W10688278 is available from your 
dealer or an authorized parts distributor. The chimney extension 
replaces the upper chimney shipped with the range hood.
Venting Requirements
(vented models only)
 
Vent system must terminate to the outdoors except  
for non-vented (recirculating) installations.
 
Do not terminate the vent system in an attic or other 
enclosed area.
 
Do not use 4" (10.2 cm) laundry-type wall cap.
 
Use metal vent only. Rigid metal vent is recommended. 
Plastic or metal foil vent is not recommended.
 
The vent system must have a damper. If the roof 
or wall cap has a damper, do not use the damper 
supplied with the range hood.
For the Most Efficient and Quiet Operation:
 
Use a straight run or as few elbows as possible.
 
Use no more than three 90° elbows.
 
Make sure there is a minimum of 24" (61 cm) of straight 
vent between the elbows if more than 1 elbow is used.
 
Do not install 2 elbows together.
 
Use vent clamps to seal all joints in the vent system.
 
Use caulking to seal exterior wall or roof opening 
around the cap.
 
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed 
to minimize conduction of outside temperatures as part of the 
vent system. The damper should be on the cold air side of the 
thermal break.
The break should be as close as possible to where the vent 
system enters the heated portion of the house.
A
B
C
D
E
F
A. 12
1
/
4
" (31.1 cm)
B. 13
3
/
16
" (33.5 cm)
C. *29
3
/
4
" (75.6 cm) min. 44
13
/
16
" (113.8 cm) max. 
**29
3
/
4
" (75.6 cm) min. 49
13
/
16
" (126.5 cm) max.
D. 3
1
/
2
" (8.9 cm)
E.  36" (91.4 cm)
F. 25
3
/
16
" (64 cm)
A
B
D
C
A.  Countertop height
B.  Hood height from ceiling to bottom 
of the range hood filter surface: D-A-C=B
C.  Hood height: 24" (61 cm) min. from electric 
cooking surface, 27" (68.6 cm) min. from gas 
cooking surface, suggested 36" (91.4 cm) max.
D.  Ceiling height