HE120, HE160 HUMIDIFIER INSTALLATION KIT
69-1571
4
CAUTION
Chemical Hazard. 
Can cause personal injury or equipment 
damage.
Do not use any line connected to an air 
conditioner.
Do not use gas line.
3.
Use the self-piercing saddle valve (included) to tap 
into the water supply line at the location selected. 
See Fig. 6. If tapping into galvanized pipe, drain 
line and pre-drill 3/16 in. tap for saddle valve.
NOTE:
The saddle valve is not designed to regulate 
water flow. The valve is either open or closed.
IMPORTANT
To prevent debris from clogging the solenoid in-
line filter, be sure to install the saddle valve han-
dle pointing toward the ceiling.
Fig. 6. Installing saddle valve.
4.
Use 1/4 in. (6 mm) OD tubing and connect saddle 
valve to float valve (see Fig. 7).
NOTE:
For HE120, use plastic compression nut for float 
connection.
a. Place compression nut over tubing.
NOTE:
For HE160, use brass expander insert for float 
connection.
b. Install brass insert into end of tubing.
NOTE:
A compression ring is required only at the tub 
end connected to the saddle valve.
c. Slide the plastic compression ring over the 
tubing. (Discard copper compression ring pro-
vided with valve.)
NOTE:
To prevent leaking, use plastic (Delrin) sleeve 
rings with plastic tubing. Use copper sleeve 
rings only with copper tubing.
d. Insert the tubing into the float valve fitting and 
support the valve while tightening the compres-
sion nut.
NOTE:
Do not over-tighten the compression nut. Mod-
erate tightness prevents leaking.
e. Repeat steps a. through d. for saddle valve fit-
ting.
f.
Secure tubing with clamps provided.
Fig. 7. Installing feed tubing.
5.
Connect a 3/8 in. (10 mm) overflow tube to the 
humidifier overflow fitting and run to the floor drain 
or bucket if floor drain is not available.
a. Insert overflow fitting. (HE160 fitting is provided 
in the kit. HE120 fitting is provided with humidi-
fier; position it in hole opposite of float.)
NOTE:
Be sure to install water pan with overflow posi-
tioned over fitting.
b. Slide the overflow clamp over the tubing.
c. Push the tubing over the overflow fitting on the 
humidifier.
d. Hand-tighten the clamp around the tubing to 
secure the overflow tubing.
e. Fasten the overflow tubing (can use duct tape) 
along the route to prevent movement and 
ensure downward slope for correct drainage.
NOTE:
Cut tubing to correct length so the tubing termi-
nates at the drain or bucket.
Adjusting HE160 Water Level (Fig. 8)
1.
Test fit the disk assembly in the humidifier.
2.
Turn on the water supply and check for leaks.
3.
Adjust the float assembly so the water height just 
covers the disks; verify that the water is within the 
range of the textured bands inside the basin. 
4.
Adjust the float, as necessary.
5.
Secure the float adjustment nut with a 9/16 in.    
(15 mm) wrench.
6.
Remove the disk and drain the water before begin-
ning the bypass installation.
M20175
SCREW DRIVER
WATER LINE
M20176
BRASS COMPRESSION NUT
PLASTIC 
COMPRESSION RING