About your new thermostat
SETUP
WIRING
ASSIST
ANCE
TROUBLESHOOTING
If labels do not match letters on the thermostat, check 
the chart below and connect to terminal as shown here 
(see notes, below).
Wiring—Conventional System
If wires will be connected to both 
R
 and 
Rc
 
terminals, remove metal jumper (see page 6).
Do not use 
C
 or 
X
. Wrap bare end of wire with 
electrical tape.
If you have a heat pump without auxiliary/backup 
heat connect O or B, not both. If you do not have 
heat pump, do not connect B. Wrap bare end of 
wire with electrical tape.
Place a jumper (piece of wire) between Y and W/
Aux if you are using a heat pump without auxiliary/
backup heat.
B       O       G       Y  W/
AUX
NOT
USED
R      Rc
M32726
4