About your new thermostat
SETUP
WIRING
ASSIST
ANCE
TROUBLESHOOTING
If labels do not match letters on the thermostat, check
the chart below and connect to terminal as shown here
(see notes, below).
Wiring—Conventional System
If wires will be connected to both
R
and
Rc
terminals, remove metal jumper (see page 6).
Do not use
Do not use
C
or
X
. Wrap bare end of wire with
electrical tape.
If you have a heat pump without auxiliary/backup
If you have a heat pump without auxiliary/backup
heat connect O or B, not both. If you do not have
a heat pump, do not connect B. Wrap bare end of
wire with electrical tape.
Place a jumper (piece of wire) between Y and W/
Place a jumper (piece of wire) between Y and W/
Aux if you are using a heat pump without auxiliary/
backup heat.
B O G Y W/
AUX
NOT
USED
R Rc
M32726
4
4