69-2580ES—01 24
SETUP
WIRING
ASSIST
ANCE
TROUBLESHOOTING
Wiring—Heat Pump
Alternate wiring (for heat pumps with auxiliary or 
backup heat only)
If labels do not match letters on the thermostat, check 
the chart below and connect to terminal as shown here 
(see notes, below).
Wiring complete, return to Step 7.
Leave metal jumper in place, connecting R & Rc terminals.
If your old thermostat had both V and VR wires, stop now and 
contact a qualified contractor for help.
If your old thermostat had separate O and B wires, wrap the B 
wire in electrical tape and do not connect.
If your old thermostat had Y1W1 and W2 wires, stop now and 
contact a qualified contractor for help.
Do not use C or X wire. Do not use B wire if you already have O 
wire. Wrap bare end of wire with electrical tape.
Do not use L wire. Wrap bare end of wire with electrical tape.
If your old thermostat had E and Aux wires (or alternate wires), 
connect both wires to Aux terminal.
5
6
7
M32728
2
7
4
AUX
W
W1
W2
F
B
O
G
H
C
RC
V
VR
B
X
R
M
Y1
Y
E
7
X
X2
L
F
6
5
3
2
1
B       O       G       Y 
W/
AUX
NOT
USED
R      Rc