Zanussi ZHP9022X ユーザーズマニュアル

ページ / 52
GB     
 
 
 
 
 
 
 
          7
Connections
Ducting Version AirExhaust System
When  installing  the  hood  in  ducting  version,  a  rigid  or
a  flexible  pipe  with  the  diameter  corresponding  to  the
flange  diameter  is  used  in  order  to  connect  the  hood
to the air outlet piping.
•  Fix the pipe with an adequate quantity of pipe clamps
(not supplied).
•  Remove possible charcoal filters.
Recirculation Version AireOutlet
•  Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood.
•  Insert the flange
10a on the hood body outlet.
•  Connect  the  flange  to  the  outlet  on  the  shelf  over
the hood using a flexible or rigid pipe ø120 mm.
•  Fix the pipe in position using sufficient pipe clamps
(not supplied).
•  Fix the directional grille
8 on the recirculation air outlet
using the 2 screws
12e (2,9 x 12,7) provided.
•  Ensure that the activated charcoal filters have been
inserted.
12e
8
Electrical Connection
•  Connect  the  hood  to  the  mains  through  a  two-pole
switch having a contact gap of at least 3 mm..