Technical characteristics
Technical characteristics of water heaters are given below in Table 1, 2.
Table 1
Table 2
insulation that allows to efficiently retain accumulated heat and save energy.
5. Temperature controller: accurate and reliable water temperature control.
6. FSQ models equipped wiht temperature display shows current water tem-
perature in water heater tanks.
7. Internal tanks and all internal components are made out of SUS 304 stain-
less steel with walls 1.2 mm thick.
8. The water heater is equipped with an anode bar to protect the internal 
tank from corrosion and decrease scale generation on the heating element.
Description
Units
SWH FSM1 30 V/ 
SWH FSM2 30 H
SWH FSM1 50 V/ 
SWH FSM2 50 H
SWH FSM1 80 V/ 
SWH FSM2 80 H
SWH FSM1 100  V/ 
SWH FSM2 100 H
Rated voltage
V/Hz
~230/50
~230/50
~230/50
~230/50
Rated current
A
8.7
8.7
8.7
8.7
Rated power
W
2000
2000
2000
2000
Stage power
W
800/1200/2000
800/1200/2000
800/1200/2000
800/1200/2000
Tank capacity
L
30
50
80
100
Rated 
pressure
Mpa
0,7
0,7
0,7
0,7
Water 
protection 
class
IPX4
IPX4
IPX4
IPX4
Heating time, 
at Δ 30 ºC
min
21
43
64
79
Appliance 
dimensions
mm
430х230
430х230
490х270
490х270
Weight
kg
?
?
?
?
Description
Units
SWH FSQ1 30 V/ 
SWH FSQ2 30 H
SWH FSQ1 50 V/ 
SWH FSQ2 50 H
SWH FSQ1 80 V/ 
SWH FSQ2 80 H
SWH FSQ1 100  V/ 
SWH FSQ2 100 H
Rated voltage
V/Hz
~230/50
~230/50
~230/50
~230/50
Rated current
A
8.7
8.7
8.7
8.7
Rated power
W
2000
2000
2000
2000
Stage power
W
800/1200/2000
800/1200/2000
800/1200/2000
800/1200/2000
Tank capacity
L
30
50
80
100
Rated 
pressure
Mpa
0,7
0,7
0,7
0,7
Water 
protection 
class
IPX4
IPX4
IPX4
IPX4
Heating time, 
at Δ 30 ºC
min
21
43
64
79
Appliance 
dimensions
mm
430х230
430х230
490х270
490х270
Weight
kg
?
?
?
?
Factual year  
energy 
consumption
kW•h
335,8
452,6
481,8
518,3
Constant daily 
heating loss
kW•h / 
day
0,98
1,23
1,33
1,45
Description
Units
SWH FSM1 30 V/ 
SWH FSM2 30 H
SWH FSM1 50 V/ 
SWH FSM2 50 H
SWH FSM1 80 V/ 
SWH FSM2 80 H
SWH FSM1 100  V/ 
SWH FSM2 100 H
Factual year  
energy 
consumption
kW•h
335,8
452,6
481,8
518,3
Constant daily 
heating loss
kW•h / 
day
0,98
1,23
1,33
1,45