IMPORTANT!
To provide reliable operation and safe use of the water heater, 
prior to the first run check if it is properly connected to the 220V 
AC mains. The water heater to be connected must be securely 
linked with the earth circuit of your electric mains.  The 
waterheater must be grounded properly, otherwise it is extremly 
dangerous for life safety.
ENGLISH
7. WATER HEATER OPERATION
1. At first, open one of the separable taps at the water heater outlet, 
then open the inlet tap. The electric water heater will start filling with 
water. When water flows from separable tap freely, it means the water 
heater is fully filled with water and you can close the separable tap.
NOTE:
During normal operation the cold water supply valve must be 
opened.
2. Plug the power cord into the outlet
3. Turn the thermostate handle (fig. 4,5) clockwise and set the desirable 
temperature.  The  temperature  can  be  set  from  +35°C  (±5° )  (MIN" 
position of the thermostat knob) up to 70°C (±5° ) (rightmost "MAX" 
position of the thermostat knob). To reduce the water temperature turn 
the handle anticlockwise.
4. Water   temperature keeps   up   by   the   thermostate automatically. 
When water temperature reach the set level, Heating is automatically 
switched  off.  At  that,  the  indicator  lamp  in  the  lower  part  of  the 
appliance extinguishes. When the temperature wil be lower then set, 
the heating will automaticlly start again and the indicator lamp lights 
up.
5. To turn off the waterheater, turn the handle to the closest left position 
«      » and unplug the power cord or disconnect the appliance from the 
power supply.
IMPORTANT!
The outlet must be designed for rated current not less than 10A, 
electric cable with copper core must have cross section not less 
than 3x1.5 mm2 (for copper).
IMPORTANT!
Optimum   position  on  the  control  panel  corresponds  to  the 
optimum water heating temperature of 58 +/-2°C, at which:
1. The user is less likely to get burned in case when the outlet 
water temperature is incorrectly adjusted.
2. A sufficient amount of hot water is obtained after mixing with 
cold water, at a lesser power energy consumption.
3. Less scale is generated on the heating element and internal 
surfaces of the water heater.
ATTENTION!
Water can start to drip from the opening of safety  valve  then 
heating process is going. It s impossible to avoid leakage of 
water and you can t  prevent this! Locking of valve may cause 
rupture of the inner tank in case  of  failure.
www.timberk.com   electric storage water heater