Cisco Cisco UCS C3260 Rack Server データシート

ページ / 52
Cisco UCS C260 M2 High-Performance Rack-Mount Server
50
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Power Specifications
The general power specifications for the C260 M2 server are listed in 
.
Table 30  UCS C260 M2 Dimensions and Weight
1
Notes . . .
1. The system weight given here is an estimate for a fully configured system and will vary depending on the 
number of peripheral devices and power supplies.
Parameter
Value
Height
3.5 in. (8.9 cm)
Width (including rack-mount flanges)
18.95 in.(48.1 cm)
Depth (including slide-rail brackets)
31.5 in. (80 cm)
Front Clearance
3 in. (7.62 cm)
Side Clearance
1 in. (2.54 cm)
Rear Clearance
6 in. (15.24 cm)
Weight (maximum configuration, including slide 
rail brackets and cable management arm)
92 lbs (41.7 kg)
*
Table 31  UCS C260 M2 Power Specifications
Description
Specification
AC input voltage
100 to 127 VAC nominal (Range: 90 to 264 VAC)
AC input frequency
50 to 60 Hz nominal (Range: 47 to 63 Hz)
Maximum AC input current
10 A at 100 VAC
Maximum AC inrush current
30 A peak sub-cycle duration
Maximum output power for each 
power supply
1200 W 
Power supply output voltage
Main power: 12
 
VDC 
Standby Power: 5 VDC
Power supply efficiency
94% Peak, complies with 80Plus Gold Standard
NOTE:  AC input connector is an IEC 320 C-14 15A/250VAC power inlet.