Cisco Cisco C880 M4 Server
Appendix A Functions Provided by the Cisco C880 server
A.1.3
A.1.3
Monitoring and reporting functions
51
C122-E175-01EN
operation
Minor item
Description
Boot device selection by UEFI Boot Manager, boot
option setting
option setting
Scheduled operation
Automatic power-on/off at specified date and time
specification
specification
Wake On LAN
Power-on via network
Automatic
recovery
recovery
Degraded operation
Automatic degraded operation on CPU, DIMM, SB etc
Reserved SB
SB automatic switching from faulty SB to Reserved
SB
SB
ASR
Automatic restart of system when failure occurs
Continuous
operation
operation
Continuous operation
Recovery by MMB or BMC reset, continuous system
operation
operation
Ecological
operation
operation
Power consumption
management
management
Cabinet power consumption monitoring, notification to
higher-level software
higher-level software
PSU power-on count control
PSU power-on control only as needed
FAN speed control
Optimum control of FAN speed
Time
synchronization
synchronization
NTP client
NTP client
A.1.3 Monitoring and reporting functions
TABLE A.3 Monitoring and reporting functions
operation
Minor item
Description
Hardware
monitoring and
reporting
monitoring and
reporting
Hardware problem
monitoring
monitoring
Hardware problem monitoring by MMB/BMC/UEFI
System problem monitoring Watchdog Timer monitoring by MMB/UEFI
Power control problem
monitoring
monitoring
Power control sequence problem monitoring
FAN speed problem
monitoring
monitoring
Fan speed problem monitoring
Voltage problem
monitoring
monitoring
Voltage problem monitoring
Temperature problem
monitoring
monitoring
Temperature problem monitoring
Hardware proactive
monitoring
monitoring
Proactive monitoring of CPU, DIMM, and HDD
hardware failures
hardware failures
External reporting
External reporting by e-mail, SNMP
Event monitoring
Sensor-detected event monitoring
Threshold monitoring
Threshold monitoring of temperature, power voltage,
and fan speed
and fan speed
Status display
LED display
Display of MMB and system status
Location display (Location LED)
Faulty component display
Location display (Location LED)
Faulty component display
Eco-related status display
Cabinet power consumption display
FAN speed display
PSU/DDC power-on status display
Temperature display
Eco status acquisition from higher-level software
(SNMP)
FAN speed display
PSU/DDC power-on status display
Temperature display
Eco status acquisition from higher-level software
(SNMP)