Cisco Cisco UCS C240 M3 Rack Server データシート

ページ / 100
Cisco UCS C240 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)
CONFIGURING the SERVER
55
STEP 14
SELECT NIC MODE (OPTIONAL)
By default, the C240 M4 server NIC mode is configured to be Shared LOM Extended. This NIC 
mode allows any LOM port or adapter card port to be used to access the Cisco Integrated 
Management Controller (CIMC). The Cisco VIC card must be installed in a slot with NCSI support.
To change the default NIC mode to Dedicated, select the UCSC-DLOM-01 PID shown in 
In Dedicated NIC mode, the CIMC can be accessed only through the dedicated management port. 
See 
 for the location of the management port.
To change the default NIC mode to Cisco Card Mode, select the UCSC-CCARD-01 PID shown in 
. In this mode, you can assign an IP address to the CIMC using DHCP and from there you 
can fully automate your deployment.
For more details on all the NIC mode settings, see
 
Table 26
  Dedicated NIC Mode Ordering Information
Product ID (PID)
PID Description
UCSC-DLOM-01
Dedicated Mode BIOS setting for C-Series Servers
UCSC-CCARD-01
Cisco Card Mode BIOS setting for C-Series Servers