Cisco Cisco UCS C3260 Rack Server データシート

ページ / 90
Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
88
TECHNICAL SPECIFICATIONS
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
Environmental Specifications
The power specifications for the C240 M3 server are listed in 
Input connector
3 wire Connector (Molex MINIFIT SR. R/A )
Table 48  UCS C240 M3 Environmental Specifications
Parameter
Minimum
Temperature operating
41 to 104° F (5 to 40° C)
derate the maximum temperature by 1°C per every 305 m of 
altitude above sea level
Temperature nonoperating
–40 to 149°F (–40 to 65°C)
Humidity (RH) operating, 
non-condensing
10 to 90%
Altitude operating
0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating
0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure 
A-weighted per ISO7779 LWAd (Bels) 
Operation at 73°F (23°C) 
5.8
Sound Pressure level, Measure 
A-weighted per ISO7779 LpAm (dBA) 
Operation at 73°F (23°C) 
43
Table 47  UCS C240 M3 LFF Power Specifications (930 W DC V2 power supply)  (continued)
Description