Cisco Cisco UCS C3260 Rack Server データシート

ページ / 60
Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server
56
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Power Specifications
The general power specifications for the C200 M2 SFF server are listed in 
Table 27  UCS C200 M2 Dimensions and Weight
1
Notes . . .
1. The system weight given here is an estimate for a fully configured system and will vary depending on the 
number of peripheral devices and power supplies.
Parameter
Value
Height
1.7 in. (4.32 cm)
Width
16.92 in.(43.0 cm)
Depth
27.8 in. (70.60 cm)
Front Clearance
3 in. (76 mm)
Side Clearance
1 in. (25 mm)
Rear Clearance
6 in. (152 mm)
Weight
33.00 lbs (14.97 kg)
*
Table 28  UCS C200 M2 SFF Power Specifications
Description
Specification
AC input voltage
100 to 127 VAC nominal (Range: 90 to 264 VAC)
AC input frequency
50 to 60 Hz nominal (Range: 47 to 63 Hz)
Maximum AC input current
8 A at 100 VAC
Maximum AC inrush current
30 A peak sub-cycle duration
Maximum output power for each 
power supply
650
 
Power supply output voltage
Main power: 12
 
VDC 
Standby Power: 5 VDC
Power supply efficiency
92% Peak, complies with 80Plus Gold Standard
NOTE:  AC input connector is an IEC 320 C-14 15A/250VAC power inlet.