Summary Tables of Changes 
 
 
36
  
 
Specification Update 
 
 
Errata for Intel
®
 Celeron
®
 Processor 500 Series for Platforms Based 
on Mobile Intel
®
 965 Express Chipset Family 
Number 
Stepping  Stepping  Stepping 
Plans 
Errata 
A-1 
E-1 
M-1 
AH1 
No Fix  Writing  the  Local  Vector  Table  (LVT)  When  an  Interrupt  Is 
Pending May Cause an Unexpected Interrupt 
AH2 
No Fix  LOCK# Asserted During a Special Cycle Shutdown Transaction May 
Unexpectedly Deassert 
AR3 
 
 
 
No Fix  Erratum Removed 
AH4 
No Fix  VERW/VERR/LSL/LAR Instructions May Unexpectedly Update the 
Last Exception Record (LER) MSR 
AH5 
No Fix  DR3 Address Match on MOVD/MOVQ/MOVNTQ Memory Store 
Instruction  May  Incorrectly  Increment  Performance  Monitoring 
Count for Saturating SIMD Instructions Retired (Event CFH) 
AH6 
 
 
Fixed  SYSRET May Incorrectly Clear RF (Resume Flag) in the RFLAGS 
Register 
AH7 
No Fix  General  Protection  Fault  (#GP)  for  Instructions  Greater  than  15 
Bytes May Be Preempted 
AH8 
No Fix  Pending x87 FPU Exceptions (#MF) Following STI May Be Serviced 
Before Higher Priority Interrupts 
AH9 
No Fix  The Processor May Report a #TS Instead of a #GP Fault 
AH11 
No Fix  A Write to an APIC Register Sometimes May Appear to Have Not 
Occurred 
AH12 
No Fix  Programming the Digital Thermal Sensor (DTS) Threshold May 
Cause Unexpected Thermal Interrupts 
AH13 
No Fix  Count Value for Performance-Monitoring Counter 
PMH_PAGE_WALK May Be Incorrect 
AH14 
No Fix  LER MSRs May Be Incorrectly Updated 
AH15 
No Fix  Performance Monitoring Events for Retired Instructions (C0H) 
May Not Be Accurate 
AH16 
No Fix  Performance Monitoring Event For Number Of Reference Cycles 
When The Processor Is Not Halted (3CH) Does Not Count 
According To The Specification 
AR16 
 
 
Fixed  Using 2M/4M Pages When A20M# Is Asserted May Result in 
Incorrect Address Translations 
AH18 
No Fix  Writing Shared Unaligned Data that Crosses a Cache Line without 
Proper Semaphores or Barriers May Expose a Memory Ordering 
Issue 
AH19 
No Fix  Code Segment Limit Violation May Occur On 4 Gigabyte Limit 
Check 
AH20 
 
 
Fixed  FP Inexact-Result Exception Flag May Not Be Set