Cisco Cisco IOS Software Release 12.2(58)SE

ページ / 22
 
17
Release Notes for the Cisco Catalyst Blade Switch 3020 for HP, Cisco IOS Release 12.2(58)SE and Later
OL-24325-01
Documentation Updates
The workaround is to disable IPv6 MLD snooping on the switch.
CSCtl80678 
The port manager callback might cause more than 90% CPU usage for up to 20 minutes under these 
conditions: 
Link comes up simultaneously on multiple dot1q trunk ports. 
VLAN Trunking Protocol (VTP) pruning is enabled.
The workaround is to disable VTP pruning. 
CSCto62631
A switch running Cisco IOS Release 12.2(58)SE might reload if:
SSH version 2 is configured on the switch, and
a customized login banner was configured by using the banner login message global 
configuration command
Use one of these workarounds:
Disable the login banner by entering the no login banner command.
Disable SSH on the switch.
Downgrade to a software version prior to Cisco IOS Release 12.2(58)SE.
Documentation Updates
Note
The “Supported MIBs” appendix is no longer in the software configuration guide. To locate and 
download MIBs for a specific Cisco product and release, use the Cisco MIB Locator:
Updates to the Software Configuration Guide
Correction to the “Unsupported Commands” Chapter
The “Miscellaneous” section of the “Unsupported Commands” chapter should include the logging 
discriminator
 global configuration command.