Cisco Cisco SG200-26P 26-port Gigabit PoE Smart Switch

ページ / 5
Release Notes for Cisco Small Business 200E Series Advanced Smart Switches Version 1.0.7.4
Release Notes
Problem:
The configured time settings will not be preserved upon a reboot, 
regardless of the method used to set them.
Solution:
Manually reset the time upon reboot.
Problem:
It may take up to 5 minutes for Bonjour to detect the switch after a 
reboot.
Solution:
There is no workaround.
Problem:
With a configuring PC attached to port g1, the MAC address binds to 
the port. After disconnecting from the switch, the PC can still connect to the switch 
and manage the DUT on other ports if using the same MAC address.
Solution:
There is no workaround.
Problem:
When using Internet Explorer version 6 the Filter label is displayed 
vertically.
Solution:
Use Internet Explorer version 8 or a different browser.
Problem:
Selected special characters such as: ",',%,!,?,×,÷ are not allowed in any 
GUI/CLI user-input fields (e.g. password, vlan name, snmp community fields, 
hostname, etc.). In addition, the whitespace/blank is not supported only in the 
Password field.
Solution:
It is possible to utilize a subset : ",',%,!,? via CLI configurations, however, 
it is recommended that they should not be used due to possible compatibility 
issues. If a user had provisioned this subset of characters in previous load via CLI, 
such as the password, then the user can continue to access via GUI using these 
special characters.
Problem:
When the SG200-08P is acting as a Powered Device (PD) without a 
connected power adapter, and is being served by an SG200-08P acting as a 
Power Sourcing Equipment (PSE), the total power given to the PD will be 15.4w. 
This power is used to run the PD thus yielding approximately half of that as 
available power to run other equipment such as a single Cisco PVC300 IP Camera 
at 7.2w. Any addition equipment being powered on by the other PoE port will cause 
the PD to reboot continuously.
Solution:
It is highly recommended that the PD have its own power supply so that 
it acts as a PSE and not a PD.
Problem:
When using Internet Explorer version 6 with the Japanese language, the 
Filter label is displayed vertically.
Solution:
Use Internet Explorer version 8 or a different browser.