Description 
This interface returns the TP structure for a specific TP name. 
For the PTP on protection equipment in a 1_FOR_N protection group, Prime Optical reports 
only the AlarmReporting for the LayeredParameters of that PTP. 
For PTPs, the additionalInfo attribute list contains the LinkIntegrityTimer attribute value if the 
selected card is one of the following (see also 
):  
•  CE-100T-8 or CE-MR-6 on ONS 15310 MA SONET or ONS 15310 MA SDH 
•  CE-100T-8 on ONS 15310 CL 
•  CE-100T-8 or CE-MR-10 on ONS 15454 SONET or ONS 15454 SDH 
For PTPs, the additionalInfo attribute list contains the LinkIntegrityTimer and 
LinkIntegrityDisable attribute values if the selected card is one of following: 
•  CE-1000-4 and G1000_4 on ONS 15454 SONET or ONS 15454 SDH 
For PTPs, the layeredParameters and additionalInfo attribute lists contain the OTU1 and OTU2 
attribute values if the selected card is one of the following: 
•  AR-XP (ONS15454 SONET and ONS15454 SDH) 
•  AR-MXP (ONS15454 SONET and ONS15454 SDH) 
For PTPs, the additionalInfo attribute list contains the OTU2 protection regeneration attribute 
value if the selected card is one of the following: 
•  AR-XP (ONS15454 SONET and ONS15454 SDH) 
•  AR-MXP (ONS15454 SONET and ONS15454 SDH) 
For PTPs, the additionalInfo attribute list contains the AUTO attribute value if the selected card 
is one of the following: 
•  AR-XP (ONS15454 SONET and ONS15454 SDH) 
•  AR-MXP (ONS15454 SONET and ONS15454 SDH) 
For more information on AR-XP and AR-MXP cards, see 
 
For CPT 200, CPT 200 SDH, CPT 600, and CPT 600 SDH, additional connectionless TP information 
can be set. For more information, see 
. 
For a list of layered parameters returned for each layer, see 
. Layered parameters are not returned for passive units. The MS-ISC card does 
not have layered parameters. 
The OTL lines/internal ports of CXP Port on the 100G_LC cards do not have layered parameters.   
Parameters 
Name
 
Type
 
Input/ Output
 
Description
 
tpName
 
globaldefs::NamingAttributes_T
 
In
 
Name of the TP to retrieve.
 
TP
 
terminationPoint::TerminationPoint_T
 
Out
 
Retrieved TP.