Cisco Cisco Prime Optical 9.6 開発者ガイド

ページ / 818
Cisco Prime Optical 9.6.3 GateWay/CORBA Programmer Reference Guide 
OL-28047-01
 
 
236
 
The TraceMode parameter can be modified. The DisableFDIonTTIM parameter is disabled when 
TraceMode is set to MANUAL and enabled when TraceMode is MANUALNOAIS. 
The setTPData interface does not apply to the following ML-series card parameters that are 
configurable through Cisco IOS: 
•  Admin state, MTU size, and COS accounting for POS and Ethernet interfaces. 
•  Speed, duplex, and flow control for Ethernet interfaces. 
Prime Optical supports the following automatic laser shutdown parameters on PTPs. These 
parameters are not defined by the TMF. 
•  ALSMode 
•  PulseWidth 
•  RecoveryInterval 
•  RestartLaser 
If the equipment is the protecting equipment in a 1_For_N protection group, Prime Optical sets 
the PTPs on the equipment to AlarmReporting. 
Prime Optical supports only the following parameters for FTPs: 
•  TrailTraceExpectedRx 
•  TrailTraceMonitor 
For valid values for each parameter, see Table 3-4 in 
 
For PTPs, the layeredParameters and additionalInfo attribute lists contain the OTU1 and OTU2 
attribute values if the selected card is one of the following: 
•  AR-XP (ONS15454 SONET and ONS15454 SDH) 
•  AR-MXP (ONS15454 SONET and ONS15454 SDH) 
For PTPs, the additionalInfo attribute list contains the OTU2 protection regeneration attribute 
value if the selected card is one of the following: 
•  AR-XP (ONS15454 SONET and ONS15454 SDH) 
•  AR-MXP (ONS15454 SONET and ONS15454 SDH) 
For PTPs, the additionalInfo attribute list contains the AUTO attribute value if the selected card 
is one of the following: 
•  AR-XP (ONS15454 SONET and ONS15454 SDH) 
•  AR-MXP (ONS15454 SONET and ONS15454 SDH) 
For more information on AR-XP and AR-MXP cards, see
 
For CPT 200, CPT 200 SDH, CPT 600, CPT 600 SDH, you can set the attributes the same as those 
of the ONS 15454 SONET and ONS 15454 SDH. 
You must use the Prime Optical client to set other TP parameters. 
Invoking this method from the NMS is a synchronous call. 
AVC notifications are not sent when PTP attributes are modified by a user.