Name
 
Value
 
Description
 
timeSlotRestriction
 
Integer, 1 to 192 for 
SONET and 1 to 64 for 
SDH.
 
You can select a specific STS/VC-4 when using 
autoroute with constraints. The STS/VC-4 is 
maintained around the ring. If the same STS/VC-4 
is not available for the entire circuit route, a 
warning message is displayed.
 
includedProtectedME
 
String
 
The parameter must match the name of any 
ManagedElement which you have requested to 
be included in the protected path of an OCHNC 
or OCHCC circuit.
 
For example:
 
EMS = Cisco Systems/CTM ManagedElement = 
myNE
 
Add the following parameter to configure a 
routing constraint:
 
includedProtectedME = myNE
 
excludedProtectedME
 
String
 
Must match the name of any ManagedElement 
which you have requested to be excluded from 
the protected path of an OCHNC or OCHCC 
circuit. See the parameter includedProtectedME 
for the scenario.
 
overlayRing
 
String
 
Values can be:
 
• 
 True—Indicates that an Overlay Ring SNC is 
allowed. You can create an Overlay Ring SNC 
only by using CTP Inclusions to pass the 
complete route from the SNC to the Prime 
Optical Server.
 
• 
False—Indicates that an Overlay Ring SNC is 
not allowed.
 
startOdu1
 
Integer
 
Number of initial ODUs used by the circuit (for 
AR-XP, AR-XPE, and AR-MXP cards).
 
endOdu1
 
Integer
 
Number of final ODUs used by the circuit (for AR-
XP, AR-XPE, and AR-MXP cards).
 
startTs
 
Integer
 
Number of initial time slots in the startOdu 
number used by AR-XP and AR-MXP cards. For 
AR-XPE, startTs represents Start Odu0.
 
endTs
 
Integer
 
Number of final time slot in the endOdu number 
used by AR-XP and AR-MXP cards. For AR-XPE, 