Setting up Input Information 
 
OL-31087-01 
167 
 
3  In the Signal Lock Period field, enter the time, in seconds, the unit must wait for 
a signal lock before declaring that the signal is not usable and move on to the 
next search location in the search path. You can enter a value in the range from 5 
to 255 seconds. The default is 30 seconds. 
4  In the Signal Loss Period field, enter the time, in seconds, the unit must wait 
(after detecting a signal loss) before declaring a disaster. You can enter a value in 
the range from 5 to 2160000 seconds. The default is 30 seconds. 
5  In the Signal Verify Period field, enter the time, in seconds, the unit must wait 
for the PAT table to verify the signal has a valid transport. You can enter a value 
in the range from 10 to 255 seconds. The default is 60 seconds. 
6  The Search Path area determines the search order of backup transports when a 
disaster occurs. For a list of triggers, see Disaster Recovery (on page 7). During a 
disaster, the unit will attempt to tune to the backup transport, based on the 
Search Path configured. The table displays the origin and backup channels for 
PE1 and PE2. 
The Origin column is automatically updated when the RF Input is enabled and 
configured. For more information, see Setting up the RF Input (on page 153). 
Disaster Recovery supports up to three backups. To configure Backup 1, 2, or 3: 
Click the Backup 1Backup 2, or Backup 3 radio button. 
Click Edit/Enable. A window is displayed, with tuning parameters. 
 
For information on the tuning parameters, see Setting up the RF Input (on page 153).  
For information on the Net ID field, see Setting up SI Receive Parameters (on page 
160). 
Note: The RF input in the Input Setup page must be configured to match the 
bandwidth of the backup parameters. 
Click OK