24 Type shownetwork and press Enter. The system displays the configuration
settings you just established.
25 Review the settings you established in steps 9 through 24 and choose one of the
following options:
If the settings are correct, go to step 26.
If a setting is incorrect, re-run the appropriate command and then go to step
26.
26 Type console -f and press Enter. A message appears that instructs you how to
return to the ALOM port, if needed.
27 Press Enter again.
Results:
Control transfers to the console of the RNCS server (rather than the ALOM
port).
The ok prompt appears.
28 Go to
Choices Regarding Installation (on page 8).
Configuring the ILOM Port of the Sun Netra T5220 Server
1 Type #. and then press Enter. One of the following results occurs:
The Login prompt appears.
The -> prompt appears.
2 Did the Login prompt appear after you completed step 1?
If yes, go to step 3.
If no (the -> prompt appeared), go to step 4.
3 From the login prompt on the terminal, log on using root as the username and
changeme as the password.
4 If you want to change the ILOM root password, type set /SP/users/root
password and then press Enter.
Note: Enter and re-enter the new password when prompted.
Note: Enter and re-enter the new password when prompted.
5 Complete the following steps to configure the serial management port of the
server.
a To disable DHCP for the port, type
a To disable DHCP for the port, type
set /SP/network pendingipdiscovery=static and then press Enter.
b To set the IP address of the port, type
set /SP/network pendingipaddress=<xxx.xxx.xxx> and then press Enter.
Note: Replace <xxx.xxx.xxx> with the IP address for the serial management
port.
c To set the Default Gateway for the port, type
set /SP/network pendingipgateway=<xxx.xxx.xxx> and then press Enter.
Note: Replace <xxx.xxx.xxx> with the IP address for the Default Gateway.