Cisco Headend System Release 2.7 インストールガイド
Configure the ALOM Port
4012763 Rev B
5
Configure the ALOM Port
Configuring the ALOM Port of the Sun Fire V240 Server
Now that you have successfully connected the laptop computer to the Sun Fire V240
server and logged on, complete the following steps to configure the ALOM port.
1 At the sc> prompt, type setsc if_network true and then press Enter.
1 At the sc> prompt, type setsc if_network true and then press Enter.
Result: One of the following results occurs:
If you have never before set the admin password for this server, the system
responds with a message similar to the following:
Warning: the setsc command is being ignored because the password for
admin has not been set.
Setting password for admin.
New password:
If the system detects that the admin password for this server has previously
been set, then the network management port of the Sun Fire V240 server
becomes functional.
2 Did the system display the “setting password” message described in the first
bullet of step 1?
If yes, go to step 3.
If no, go to step 4.
3 Complete the following steps if the “setting password” message, described in the
first bullet of step 1, appeared after completing step 1.
a Type the new admin password and then press Enter. The Re-enter new
a Type the new admin password and then press Enter. The Re-enter new
password prompt appears.
b Retype the new admin password and then press Enter.
c Type setsc if_network true and then press Enter. The network management
c Type setsc if_network true and then press Enter. The network management
port of the Sun Fire V240 server becomes functional.
4 Type setsc netsc_dhcp false and then press Enter. This command prevents the
Dynamic Host Configuration Protocol (DHCP) from obtaining the network
configuration.