Cisco Headend System Release 2.7 インストールガイド
Configure the ALOM Port
4012763 Rev B
7
16 Type shownetwork and then press Enter. The system displays the configuration
settings you just established.
17 Review the settings you established in steps 1 through 16 and choose one of the
following options:
If the settings are correct, go to step 18.
If a setting is incorrect, re-run the appropriate command and then go to step
18.
18 Type console -f and then press Enter. A message appears that instructs you how
to return to the ALOM port, if needed.
19 Press Enter again.
Results:
Control transfers to the console of the Sun Fire V240 server (rather than the
ALOM port).
The ok prompt appears.
Choices Regarding Installation
The Sun Fire V240 server is now ready for the installation of RNCS software. You
have the following two options:
Telnet from the DNCS to the just-configured ALOM port by following the
instructions in Connecting to the Console of the V240 Server (on page 8).
Note: Cisco recommends that you select this option in order to test the just-
Note: Cisco recommends that you select this option in order to test the just-
configured ALOM port.
Use the laptop to install the RNCS software by following the instructions in
Install the RNCS Software (on page 9).