Cisco Cisco 1 GHz GainMaker Amplifier データシート

ページ / 7
 
 
© 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 3 of 7 
Specifications 
Table 1. 
General Station Performance 
General Station Performance 
Units 
Forward 
Reverse 
Notes 
Pass band 
MHz 
54-1218 
5-85 
 
Amplifier type 
GaN 
GaAs HBT 
 
Frequency response 
dB 
± 0.5 
± 0.5 
 
Auto slope and gain range 
dB 
± 5.8 
 
Return loss 
dB 
16 
16 
Maximum AC through current (continuous) 
Amps 
15 
 
Maximum AC through current (surge) 
Amps 
25 
 
Hum modulation at 12A 
(over specified frequency range) 
dB 
70 (54
–870 MHz) 
60 (870
–1218 MHz) 
60 (5
–25 MHz) 
70 (25
–42 MHz) 
 
Hum modulation at 15A 
(over specified frequency range) 
dB 
65 (54
–870 MHz) 
60 (870
–1218 MHz) 
60 (5
–25 MHz) 
65 (25
–42 MHz) 
 
Test points (± 0.75 dB) 
dB 
-20 
-20 
 
Reference output level at 
1218MHz 
 
1002 MHz 
 
870 MHz 
 
750 MHz 
 
650 MHz 
 
550 MHz 
 
105MHz 
 
54 MHz 
dBmV 
57.0 
54.7 
53.2 
51.7 
50.4 
49.1 
40.9 
39.2 
35 (at 42 MHz) 
 
 
 
 
35 (at 5 MHz) 
 
Reference output tilt 
(54-1218 MHz) 
 
(105-1218 MHz) 
dB 
17.8 
16.1 
Table 2. 
Forward Station Performance 
Forward Station Performance 
Units 
Auto/Thermal with 12 dB I/S EQ 
Notes 
Operational gain (minimum) 
dB 
48 
Internal tilt (± 0.5 dB) at 54 MHz 
dB 
19.0 
Internal tilt (± 0.5 dB) at 105 MHz 
dB 
17.2 
Noise figure at 54, 105 MHz 
dB 
8.5 
Noise figure at 1 218MHz 
dB 
8.0 
Composite triple beat 
dBc 
68 
4, 9 
Cross modulation 
dBc 
64 
4, 5, 9 
Composite second order (high side) 
dBc 
68 
4, 9 
Composite intermodulation noise (CIN) 
dBc 
50 
4, 8, 9 
Unless otherwise noted, specifications reflect typical performance and are referenced to 68°F (20°C). Specifications are based 
upon measurements made in accordance with SCTE/ANSI standards (where applicable), using standard frequency assignments.