Cisco Cisco StadiumVision Director
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
© 2010-2011 Cisco Systems, Inc. All rights reserved.
Page 35 of 47
Identifier
Headline
Description
CSCti29596
Stopping a script will skip the "end"
state
state
Symptom: If the script is stopped by the user with the "stop"
button, the "end" state will be skipped.
button, the "end" state will be skipped.
Conditions: "End" state is a concept from V1.0, where the
last state of the script is automatically marked "end." The
configuration (actions) inside of this state is executed and then
the script is stopped. With the change to the script control in
V2.2, the "End" state concept no longer fits well with the rest
of the system. To maintain backward compatibility, the current
release will still mark the last state as "end." The “end” state is
executed if the state before the "end" is a timed state and the
script transitions to the "end" state when the timer expires.
However, this "end" state will not be executed if the user
presses the "stop" button to terminate a script.
last state of the script is automatically marked "end." The
configuration (actions) inside of this state is executed and then
the script is stopped. With the change to the script control in
V2.2, the "End" state concept no longer fits well with the rest
of the system. To maintain backward compatibility, the current
release will still mark the last state as "end." The “end” state is
executed if the state before the "end" is a timed state and the
script transitions to the "end" state when the timer expires.
However, this "end" state will not be executed if the user
presses the "stop" button to terminate a script.
Workaround: It is recommended that the user configure an
extra state and make it an empty state.
extra state and make it an empty state.
CSCti22032
Dashboard - Bulk Import Switch
fails second time w/o browser
refresh
fails second time w/o browser
refresh
Symptom: If you perform a bulk import of switch information,
then import it again, the updated description doesn’t show up
in GUI, even after browser refresh.
then import it again, the updated description doesn’t show up
in GUI, even after browser refresh.
Workaround: Refresh the browser refresh before running the
“Bulk Import Switch” command a second time.
“Bulk Import Switch” command a second time.
CSCti15964
Discovered switch data is not used
until browser refresh
until browser refresh
Symptom: On occasion, when you select Dashboard > Tools
> Settings > Switch Management > Import Switch
> Settings > Switch Management > Import Switch
or
Dashboard > Tools > Settings > Switch Management >
“Reimport MAC address to port mappings for selected
switches”
“Reimport MAC address to port mappings for selected
switches”
you need to refresh your browser before the mappings will
allow switch commands, such as “Power Cycle DMP,” to work.
allow switch commands, such as “Power Cycle DMP,” to work.
Workaround: Refresh the browser.
CSCti04341
Playlists with small number of
items in them do not generate PoP
items in them do not generate PoP
Symptom: Proof of Play reports are not generated for
playlists that contain less than 3 items.
playlists that contain less than 3 items.
Workaround: If PoP is required, create playlists that contain 3
or more items.
or more items.
CSCti00843
Error message caused by loading
StadiumVision/config/views/scriptI
nstance/all
StadiumVision/config/views/scriptI
nstance/all
Symptom: Occasionally, an error message is displayed
indicating loading of the URL fails.
indicating loading of the URL fails.
Conditions: The occurrence may appear random to the user,
often after the user performs an unrelated action on the
Control Panel UI. The potential cause for this error is the
maximum concurrent connection from the browser to the
server has been reached.
often after the user performs an unrelated action on the
Control Panel UI. The potential cause for this error is the
maximum concurrent connection from the browser to the
server has been reached.
Workaround: Click OK to dismiss the error, the UI should
recover and continue to function normally. To reduce the
likelihood of the error occurring, try increasing the concurrent
connection limit in the browser. In Firefox, increase
network.http.max-persistent-connections-per-server to 16. In
addition, close any unused browser window/tab that loads
StadiumVision applications, including the Dashboard, the
dynamic menu board application, and the unused Control
Panel application itself.
recover and continue to function normally. To reduce the
likelihood of the error occurring, try increasing the concurrent
connection limit in the browser. In Firefox, increase
network.http.max-persistent-connections-per-server to 16. In
addition, close any unused browser window/tab that loads
StadiumVision applications, including the Dashboard, the
dynamic menu board application, and the unused Control
Panel application itself.