No Forward RF Signal 
No Forward RF Signal 
The forward RF signal can be measured at the amplifier module forward input and 
forward output test points. 
 
No Forward RF Signal Troubleshooting Table 
Before you begin troubleshooting for no forward RF signal, verify that the amplifier is 
receiving the proper forward RF input signal from the upstream amplifier. 
Important: You cannot balance the amplifier without the proper forward RF input 
signal. 
Possible cause 
Solution 
No forward RF signal at the forward 
input test point. 
 
Verify that the amplifier is receiving the proper 
forward RF input signal from the upstream 
amplifier. 
Important: You cannot balance the amplifier 
without the proper forward RF input signal. 
There is forward RF signal at the 
forward input test point, but no 
signal at one or all of the forward 
output test points. 
 
Verify that the amplifier module is receiving 
the proper AC and DC voltages. Refer to No 
AC Power (on page 83) and No DC Power (on 
page 85). 
 
Verify that all the proper accessories, pads, 
EQs, and signal directors (if applicable) are 
firmly installed in the correct locations. 
 
Verify that the factory installed accessories are 
firmly installed in the correct locations. 
Note: Verifying factory installations involves 
removing the amplifier module cover. Reinstall 
the amplifier module cover properly or RF 
signal degradation may result. 
 
Replace the amplifier module. 
 
 
 