Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
 
Low or Degraded Forward RF Signal 
Possible cause 
Solution 
There is a proper forward RF signal 
at the forward input test point, but a 
low or degraded signal at one or all 
of the forward output test points. 
 
Verify that the amplifier module is receiving 
the proper DC voltages. Refer to No DC Power 
(on page 85). 
 
Verify that switch S1 is in the proper position 
for your amplifier module configuration. Refer 
to Balancing and Setup (on page 41) for more 
information. 
 
Verify that all the proper accessories, pads, 
EQs, and signal directors (if applicable) are 
firmly installed in the correct locations. 
 
Verify that the factory installed accessories are 
firmly installed in the correct locations. 
Note: Verifying factory installations involves 
removing the amplifier module cover. Reinstall 
the amplifier module cover properly or RF 
signal degradation may result. 
 
Replace the amplifier module. 
 
 
 
OL-31155-01 
89