Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
 
Balancing the Forward Path 
 
If the output tilt is less than design tilt, replace the forward input EQ with a 
higher value. 
Measure the output tilt again, and then return to step 1. 
 
To Set the Output Level 
After setting the tilt, complete the following steps to select the proper pad values for the 
amplifier. The output level of the amplifier is set by selecting the proper pad value. 
Note: If you are setting the output level of an amplifier that has not warmed up for 
approximately one hour, skip to the To Set the Output Level for a Cold Amplifier 
procedure below. 
To Set the Output Level for a Warm Amplifier 
Connect the test probe to the forward output test point. 
Measure the output level at the highest design frequency, and compare this level 
with the design level (on the design print). 
Is the measured output level within ±0.5 dB of the design level? 
 
If the output level is within ±0.5 dB of the design output level, proceed to 
Balancing the Reverse Path (on page 74). 
 
If the output level is more than the design output level, replace the forward input 
pad with a higher value pad. 
 
If the output level is less than the design output level, replace the forward input 
pad with a lower value pad. 
To Set the Output Level for a Cold Amplifier 
After setting the tilt, complete the following steps to select the proper pad values for the 
amplifier. The output level of the amplifier is set by selecting the proper pad value. 
Note: Using this procedure will result in a more accurate output level setting when 
balancing an amplifier using amplifier and coax compensation mode if the amplifier has 
had little or no warm-up period. 
Important! For the most accurate output level setting, allow the amplifier to warm up for 
approximately one hour and use the To Set the Output Level for a Warm Amplifier 
procedure above. 
Connect the test probe to the forward output test point. 
Measure the output level at the highest design frequency, and compare this level 
with the design level (on the design print), minus 1 dB
The station output level must be 1 dB lower than the output level specified by the 
design print. This reduction in output level will be offset by an increase in internal 
amplifier gain as the thermal circuit in the amplifier warms up. 
Is the measured output level within ±0.5 dB of the design level minus 1 dB
 
If the output level is within ±0.5 dB of the design output level minus 1 dB
proceed to step 5. 
 
If the output level is more than the design output level minus 1 dB, replace the 
 
OL-31155-01 
69