Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
Chapter 3    Balancing and Setup 
 
 
 
forward input pad with a higher value pad. 
 
If the output level is less than the design level minus 1 dB, replace the forward 
input pad with a lower value pad. 
Repeat steps 2 and 3 until the output level is correct. 
Proceed to Balancing the Reverse Path (on page 74). 
 
 
Forward Path Balancing for Manual Stations 
Before you begin, make sure that you have configured the amplifier module according to 
the specifications in the design print, and that the amplifier has warmed up for 
approximately one hour. 
No Switch 1 Setting for Manual Stations 
A manual station is a station that has no Bode network installed. Therefore, there is no 
interstage level correction, and Switch 1 has no effect on station operation. 
 
To Determine the Output Tilt 
Complete the following steps to determine the output tilt of the amplifier. 
Connect the test point adapter to the forward main output test point. 
 
Consult the design print to find the proper output tilt. 
Measure the output signal levels at the frequencies you used in To Verify the Input 
Signal Level (on page 45). 
To determine the actual output tilt, calculate the difference (in dB) between the levels 
 
70 
OL-31155-01