Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
Chapter 3    Balancing and Setup 
 
 
 
Note: Make sure the reverse fiber link has been properly balanced before proceeding. 
Ensure that the design value reverse output equalizer and reverse pads are installed 
in the appropriate reverse slots in the amplifier. Refer to the following diagram. 
Note: Record the pad values for each input port for later use. 
 
Proceed to To Calculate the Proper RF Signal Level (on page 76). 
 
 
To Calculate the Proper RF Signal Level 
In order to calculate the correct RF signal level to inject, you must know the following. 
 
Design Reverse Port Input Level from the design print 
 
Total Injection Insertion Loss (20 dB) 
To calculate the correct signal level to inject, add the total injection insertion loss to the 
design port input level.   
Example 
 
Design amplifier reverse port input level = 19 dBmV 
 
Total injection insertion loss = 20 dB 
The design amplifier reverse port input level plus injection insertion loss equals correct 
RF signal level to inject. 
In the example shown above, 19 dBmV + 20 dB = 39 dBmV. Therefore, you would set the 
 
76 
OL-31155-01