Cisco Reverse Amplifier Module A93146 データシート

ページ / 6
Compact EGC Amplifier Model 93251 
 
2
 
Block Diagram 
DC
DC
230 V AC
AC or DC in
TX
RX
0-18 dB
0-18 dB
0-15 dB
-20dB
TP
-20dB
TP
-20dB
TP
IN
OUT
OUT 2
OUT 1
0-15 dB
-20dB
TP
0-6 dB
-20dB
-33dB
0-18 dB
AUX
Rev.Eq.
0-20 dB
µ-
Controller
Transponder
20/25 dB
 
 
 
Overview
 
AC connection max.15A at 
remote supply 
Power supply fuse  
(2AT at 230V)
(5AT at remote supply) 
Reverse equlizer (plug-in) 
Type 74141-xx 
Input splitter  
Type 74089  0 dB link 
Type 77041  3.5/3.5 dB 
Type 77042  2/6 dB 
Type 77043  1.5/10.5dB 
Fuses (turnable) 
Choose AC-pass 
Terminal for earthing  
DC-voltage indicator  
24 V DC
Test point output 
-20 dB, directional 
Test point input 
-20 dB, bidirectional 
Compact Transponder
Type 91051/91063
Diplex Filter 
Type 75130-xxxx  
If no reverse path wanted; 
Use 0 dB link type 74089 
Mounting fittings 
(total  3 pcs.) 
AUX Plug-in module 
Equalizer     
74100-xxx
Inv.Equalizer     74190-xx
Attenuator   
77150-xx   
0 dB Link 
74069 
Output splitter  
Type 74069  0 dB link 
Type 77041  3.5/3.5 dB 
Type 77042  2/6 dB 
Type 77043  1.5/10.5dB 
Low voltage lockout 
Type 75018-xx 
Reverse Test Point 
-20 dB, directional coupled
Reverse injection Test Point
-20 dB, directional
Diplex Filter 
Type 75130-xxxx  
If no reverse path wanted; 
Use 0 dB link type 74089