Cisco Reverse Amplifier Module A93146 データシート

ページ / 6
Compact EGC Amplifier Model 93251 
 
3
 
Specifications 
 
Forward 
Units 
Description 
Notes
Frequency Range 
MHz 
47 to 862 
47 to 1000 
Gain 
dB 
Selectable 28, 34, 40 
 
Flatness 
dB 
± 0.50 
± 0.75 
Input Attenuator 
dB 
0 to 18 in 0.5 dB step 
 
Input Equalizer 
dB 
0 to 18 in 0.5 dB step 
 
Interstage Attenuator 
dB 
0 to 6 in 0.5 dB step 
 
Interstage Pre-equalizer 
dB 
0 to 15 in 0.5 dB step 
 
Input Test Point 
dB 
-20 ± 1.5 
 
Output Test Point 
dB 
-20 ± 0.50 
-20 ± 0.75  
 
Number of Outputs 
– 
1 or 2 
Return Loss  
•  Input, output port 
•  Input, output test point 
dB 
 
>18  
>20  
2, 4 
Noise Figure 
dB 
7.0 
Signal Feed Through Loss 
dB 
≤ 1.0 
 
Output Level @  42 ch CENELEC 
• CTB  ≥ 60 dB 
• CSO ≥ 60 dB 
dBµV 
 
114  
114 
6, 7 
 
Reverse
 
Units
 
Description 
Notes
Frequency Range 
MHz 
5 to 65  
5 to 200  
Gain 
dB 
Selectable 20, 25 
 
Flatness 
dB 
± 0.5  
± 0.75 
 
Input Attenuators 
dB 
0 to 20 in 0.5 dB step 
 
Output Attenuators  
dB 
0 to 18 in 0.5 dB step 
 
Output Equalizer 
dB 
0 to 15 in 0.5 dB step 
 
Test Point 
dB 
-20 ± 0.5  
 
Signal Injection Point 
dB 
-20 ± 0.5 
 
Return Loss at Test Point  
dB 
> 20 @ 5 to 10 MHz 
> 23 @ 10 to 200 MHz 
Return Loss at input and output 
dB 
> 18 
4, 8 
Output Level 
• IMD3 ≥ 60 dB 
• IMD2 ≥ 60 dB 
dBμV 
 
117 
112  
 
111 
107 
 
 
3-state Reverse Switch, EM controlled 
– 
On/-6 dB/Off 
 
Noise Figure 
dB 
≤ 7.5 
≤ 8.0 
 
Unless otherwise noted, all data given are for the amplifier with standard configuration for 1 output.