Cisco Cisco OptoStar II Driver Amplifier インストールガイド
Console-Module Control Interface, Continued
Setup Parameters
The table below lists the parameter settings of the OptoStar II forward driver
amplifier module.
amplifier module.
Setup Parameters
Description
Factory Default
RF Input Alarm
Threshold
Shows/sets upper limit and lower
limit of RF input alarm
Lower limit: 10
dBmV
Upper limit: 20
Upper limit: 20
dBmV
Output Signal
Slope Settings
Output signal slope settings (range:
0~9 dB)
0 dB
Output Signal Gain
Settings
Output signal gain settings (range:
-9~0 dB)
0 dB
Channel Load
Shows/sets analog channel
number, QAM channel number,
and delta level (dB)
Analog channel
number: 59
QAM channel
QAM channel
number: 53
Delta level: 6. 0 dB
Delta level: 6. 0 dB
Alarm ON/OFF
Shows/sets module alarm status:
ON/OFF
Alarm status: ON
Continued on next page
3-38
Operation
OL-29664-05