Problem:
You cannot configure ipv6 tunnel parameters if you previously did not 
define the mode type. (CQ140919)
Solution:
Configure the tunnel mode first when configuring an IPv6 tunnel.
Problem:
It is impossible to configure more than 255 multicast groups on an 
Sx500 switch in Router Mode. The stated limit in the documentation is 1k multicast 
groups. (CQ143282)
Problem:
If you modify an IPv6 tunnel configuration, the change will not take 
effect until you perform a shut then no shut on the tunnel interface. (CQ146071)
Solution:
You must perform a shut then no shut the tunnel interface for it to take 
effect.
Problem:
When a 10G DAC (Direct Attached Cable) is connected to the copper 
port of the SG500 using the last two ports (combo ports), the fiber link status 
display might be up even when the link is not active. 
Solution:
There is no workaround.
Problem:
When enabling IPv6 unicast-routing, the interface cannot get an ipv6 
address via auto-config. (CQ146156)
Solution:
Configure the interface using a static IPv6 address.
Japanese language files and firmware version compatibility 
guideline
Users will see a mismatch in the features between the English language and the 
Japanese language when running certain combinations of firmware and language 
files. Users will see new features added since version 1.1.1.6 in English instead of 
Japanese in the GUI when running firmware version 1.1.2.0 and higher subject to 
the following restriction:
Japanese language files version 1.1.1.6 and older are forward compatible up 
to Firmware version 1.1.2.0. For example: loading a version 1.1.1.6 language 
file onto a device running firmware version 1.2.7.76 and up will fail.
Japanese language files version 1.1.1.10 and newer are only compatible with 
firmware version 1.2.7.76 and newer.