Cisco Cisco SG200-26P 26-port Gigabit PoE Smart Switch 發佈版本通知
Release Notes for 200, 300, 500, and ESW2 Series Switches Firmware Version 1.3.5.x
21
Release Notes
Problem:
You cannot configure ipv6 tunnel parameters if you previously did not
define the mode type. (CQ140919)
Solution:
Configure the tunnel mode first when configuring an IPv6 tunnel.
Problem:
It is impossible to configure more than 255 multicast groups on an
Sx500 switch in Router Mode. The stated limit in the documentation is 1k multicast
groups. (CQ143282)
groups. (CQ143282)
Problem:
If you modify an IPv6 tunnel configuration, the change will not take
effect until you perform a shut then no shut on the tunnel interface. (CQ146071)
Solution:
You must perform a shut then no shut the tunnel interface for it to take
effect.
Problem:
When a 10G DAC (Direct Attached Cable) is connected to the copper
port of the SG500 using the last two ports (combo ports), the fiber link status
display might be up even when the link is not active.
display might be up even when the link is not active.
Solution:
There is no workaround.
Problem:
When enabling IPv6 unicast-routing, the interface cannot get an ipv6
address via auto-config. (CQ146156)
Solution:
Configure the interface using a static IPv6 address.
Japanese language files and firmware version compatibility
guideline
guideline
Users will see a mismatch in the features between the English language and the
Japanese language when running certain combinations of firmware and language
files. Users will see new features added since version 1.1.1.6 in English instead of
Japanese in the GUI when running firmware version 1.1.2.0 and higher subject to
the following restriction:
Japanese language when running certain combinations of firmware and language
files. Users will see new features added since version 1.1.1.6 in English instead of
Japanese in the GUI when running firmware version 1.1.2.0 and higher subject to
the following restriction:
•
Japanese language files version 1.1.1.6 and older are forward compatible up
to Firmware version 1.1.2.0. For example: loading a version 1.1.1.6 language
file onto a device running firmware version 1.2.7.76 and up will fail.
to Firmware version 1.1.2.0. For example: loading a version 1.1.1.6 language
file onto a device running firmware version 1.2.7.76 and up will fail.
•
Japanese language files version 1.1.1.10 and newer are only compatible with
firmware version 1.2.7.76 and newer.
firmware version 1.2.7.76 and newer.