Zebra 01407-000 ユーザーズマニュアル

ページ / 116
Installation
Connecting the Power
16
P1003643-001
TTP 1020™/TTP 1030™ Technical Manual
03/03/2009
Connecting the Power
Are you using a Zebra power supply unit?
Table 1 • Power connection
Table 2 • Current consumption
If…
Then…
No
a.
Connect the voltages according to the following illustration.
b.
At the printer end of the cable, use an AMP Mate-N-Lok connector housing 
and two contact-sockets.
Yes
a.
Make sure the line voltage selector on the power supply is set to your local 
line voltage (only PSU 01035-014).
b.
Connect the cable from the power supply to J5.
c.
Connect the power cable to the line outlet.
d.
Apply power to the printer.
Note • 
The protective ground and the 24V ground must be separated in the power supply to 
avoid ground loops!
AMP No. 350777-1
AMP No. 350689-1
Print mode
Current
Idle
150 mA
Standard text printing
4.5 A average
All black printing
6A
GND
+24 V