Zebra 01407-000 ユーザーズマニュアル

ページ / 116
59
Programming
Parameter Settings 
03/03/2009
TTP 1020™/TTP 1030™ Technical Manual
P1003643-001
Disable parallel port signaling (n5)
0
1
No. Errors are indicated on pin 12 and 15 of the parallel port
Yes
Burn time (n7)
v
0
1
2
3
4
5
6
7
8
9
10
11
12 13 14
15
%
75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150
Max speed (n8)
v
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19
mm/s
34 34 40 46 51 58 60 65 68 72 76 79 82 85 88 91 94 97 100
Presenter Loop length (n9)
Printhead pulse control * (n10)
*.
 One burn pulse means that all dots of the printhead are burned (heated up) at once. 
 
Two burn pulses mean that 50% of the dots are burned at a time, decreasing the top current and print 
speed.
 
History pulses enhance print quality, settings without history pulses can be considered as draft-mode 
settings.
v
0
3-255(18)
0
1
2
3
ON Max loop length in 
3.2cm steps 
1 burn +
history
1 burn
2 burn + 
history
2 burn
Font Attributes (n12)
Line spacing (n13)
v
0-255
0 = Standard for font 
height
Value in pixels or font height, 
whichever is the largest
Font (n14)
Tab positions (n15-n30)
v
0-7
Se
.
See 
Only the first 5 positions are stored in nonvolatile 
memory
Carriage return and line feed behavior* (n33)
*.
 v=1 is suitable for UNIX, v=2 for DOS, and v=4 for Macintosh
v
0
1
2
3
4
LF
CR/LF
CR/LF
LF
LF
Ignored
CR
Ignored
CR
CR
CR/LF
CR/LF