Samsung SSA-S3020 ユーザーズマニュアル

ページ / 80
50_
 
I/O time setup
I/O time setup
READER #1 ERROR OUTPUT SETUP
READER #1 ID Error Output Setup
Press the 
F
6
 SETUP MENU button.
Use the buttons 
4
 and 
6
 to move to the RD1 ID ERROR item and 
press 
ENT
.
You can make input when the prompt blinks.
If you enter ‘00’, no output setting is configured.
Use the keypad to enter the time for each output operation and press 
ENT
.
DR : Door relay output
AR : Alarm relay output
T1 : TTL #1 output
T2 : TTL #2 output
BZ : Buzzer output
The output time differs, depending on the time unit.
If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can 
specify between 0 and 98 seconds.
For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 54)
If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time 
unit.
READER #1 Time Schedule Error Output Setup
Press the 
F
6
 SETUP MENU button.
Use the buttons 
4
 and 
6
 to move to the RD1 T/S ERROR item and 
press 
ENT
.
The operation time for each output is the same as in “READER #1 ID Error 
Output Setup” above.
Time schedule must be confi gured before. (See Page 55 for “Time Schedule Setup”.)
READER #1 Antipassback Error Output Setup
Press the 
F
6
 SETUP MENU button.
Use the buttons 
4
 and 
6
 to move to the RD1 APB ERROR item and 
press 
ENT
.
The operation time for each output is the same as in “READER #1 ID Error 
Output Setup” above.
APB mode must be enabled before. (See Page 55 for “AntiPassBack Mode”.)
1.
2.
3.

M
1.
2.
M
1.
2.
M
5.RD1 ID ERROR
D R   A R   T 1   T 2   B Z
0 0   0 3   0 0   0 0   0 0
5.RD1 ID ERROR
D R   A R   T 1   T 2   B Z
_ 0   0 3   0 0   0 0   0 0
7.RD1 APB ERROR
D R   A R   T 1   T 2   B Z
0 0   0 3   0 0   0 0   0 0
6.RD1 T/S ERROR
D R   A R   T 1   T 2   B Z
0 0   0 3   0 0   0 0   0 0