64 – 10x Network Mini Smart Dome Camera
setup tool
Options
Determine whether or not you wish to receive Email 
notifi cation of insuffi cient capacity warnings.
ALARM IMAGE SETUP
Transfer Mode
You can select a method to send an alarm image 
from the <FTP Transfer>, <E-Mail Transfer> and 
<SD Card Record>.
<FTP Transfer>: The image is sent to the    
 specifi ed FTP address.
<E-Mail Transfer>: The image is sent to the  
 specifi ed Email address.
SD Card Record>
Insert an Micro SDHC memory card.
Confi gure the Micro SDHC memory card (refer to 
page 19 for details).
 Check the SD Card Recording option and then 
click on the [Apply] button. The SD indicator will 
then turn on and recording will commence.
To remove the Micro SDHC memory card, fi rst 
uncheck the SD Card Recording option and then 
click on the [Apply] button. 
Removing the Micro SDHC memory card while 
recording is in progress can damage the data.
Transferred Image Naming Setup
You can set the fi le name of an alarm image to 
be sent when an alarm is generated or during the 
scheduled transfer.
Pre/Post Alarm Image
You can determine which of previous or posterior 
image is to be sent.
<Number of Image>: Determines number of 
images to be sent per second. You can select 1, 2, 
3 and 5 images per second.
<Pre-Alarm Duration>: Determines time of prior 
images to be sent. You can select one from <5 sec>, 
<10 sec>, <15 sec> and <30 sec>. You can send 

M
a prior image of up to 30 seconds after an alarm is 
generated. (The maximum time is determined by the 
number of images to be sent per second.)
<Post-Alarm Duration>: Determines time of 
posterior images to be sent. You can select one 
from <5 sec>, <10 sec>, <15 sec> and <30 sec>. 
You can send a posterior image of up to 30 seconds 
after an alarm is generated. (The maximum time is 
determined by the number of images to be sent per 
second.)
ALARM INPUT SETUP
Various functions of 8 Alarm Inputs can be set up 
independently.
Input Device Setup
Select an input type from the <Off>, <NO> and 
<NC>. 
<NO>(Normal Open): It is normally open, but if it is 
close, an alarm will be generated.
<NC>(Normal Close): It is normally close, but if it is 
open, an alarm will be generated.
Activation Time
You can set time to accept an alarm to take an 
action.
<Always>: Always conducts the <Action> setting 
when an alarm is generated.
<Only Scheduled Time>: Conducts the <Action
setting for an alarm only when it occurs during the 
specifi ed time period on the specifi ed day of the 
week. The Start Time must prior to and must differ 
from the End Time.
Action
You can set an operation to be conducted when an 
alarm is generated.
<Alarm Output>: Determines alarm output port to 
which the alarm signal is to be sent.
<Output Duration>: Determines the period of time 
to output alarm signal to the specifi ed alarm output 
port when an alarm is generated. If another alarm